The double-ended mounting provides good restraint for possible movement of the tanks and, in many cases, eliminates the need for check rods. The shear beam design gives excellent performance for high capacity loading.
The double-ended mounting provides good restraint for possible movement of the tanks and, in many cases, eliminates the need for check rods. The shear beam design gives excellent performance for high capacity loading. Celtron CLB is constructed of alloy steel and is fully potted with special chemical compounds to IP67 providing excellent protection against moisture and humidity.
NTEP/OIML accuracy class NTEP IIIL Non-Approved
Maximum no. of intervals (n) 10000 multiple 1000
Y = Emax/Vmin 14000 5000 Maximum available
Standard capacities (Emax) 20k, 25k, 40k, 50k, 60k, 75k, 100k, 125k lbs
Rated output—R.O. 3.0 mV/V
Rated output tolerance 0.25 ±% of rated output
Zero balance 1 ±% of rated output
Non-linearity 0.025 ±% of rated output
Hysteresis 0.025 ±% of rated output
Non-repeatability .02 ±% of rated output
Creep error (20 minutes) 0.030 ±% of rated output
Zero return (20 minutes) 0.030 ±% of rated output
Temperature effect on min. dead load output 0.0010 0.0026 ±% of rated output/°C
Temperature effect on sensitivity 0.0010 0.0015 ±% of applied load/°C
Compensated temperature range –10 to +40 °C
Operating temperature range –20 to +60 °C
Safe overload 150 % of R.C.
Ultimate overload 300 % of R.C.
Excitation, recommended 10 VDC or VAC RMS
Excitation, maximum 15 VDC or VAC RMS
Input impedance 770±10 Ω
Output impedance 700±5 Ω
Insulation resistance >5000 MΩ
Construction Nickel-plated alloy steel
Environmental protection IP67